1Simple, accurate, and precise spectrophotometric
method has been developed and validated for the
estimation of amlodipine besylate (AML) in tablets. The
method is based on the condensation of AML with
sodium 1,2-naphthoquinone-4-sulphonate in an alkaline
medium when the reaction mixture was heated at 363K
for 1 min to form an orange-colored product. The
spectrophotometric method involved the measurement of
the colored product at 459 nm. The reaction conditions
were studied and optimized. Beer’s law was obeyed in the
concentration range of 10–20 μg·ml-1 with RSD of 0.825
and 0.559 % and molar absorption of 2.54·104, the range
of methods application is 67–133 % of the nominal
content of amlodipine besylate in the dosage forms. Розроблений та валідований простий, точний і
прецизійний спектрофотометричний метод оцінки кількісного
вмісту амлодипіну безилату у таблетках. Метод базується на
взаємодії амлодипіну безилату із натрію 1,2-нафтохінон-4-
сульфонатом у лужному середовищі, за нагрівання реакційної
суміші за 363K протягом 1 хв., з утворенням продукту помаранчевого кольору. Спектрофотометричний метод включав вимірювання оптичної густини продукту при 459 нм. При розробленні
методу вивчено та оптимізовано умови реакції. Підпорядкування
закону Бера відбувалось у діапазоні концентрацій 10–20 мкг/мл при
RSD 0,825 і 0,559%, а молярний коефіцієнт поглинання складав
2,54·104, діапазон застосування методів становить 67–133% від
номінального вмісту амлодипіну безилату у лікарськихформах.